Chapter 5: Isothermal Reactor Design: Conversion
Deriving CA and CB:
Remember that the reaction is: |
![]() |
For a gas phase system: |
![]() |
If the conditions are isothermal (T = T0) and isobaric (P = P0): |
![]() |
We must divide by the stoichiometric coefficient of our basis of calculation yielding: |
![]() |
And if the feed is equal molar, then: |
![]() |
This leaves us with CA as a function of conversion alone: |
![]() |