Select Chapter >> | TOC | Preface | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | Appendices |
Chapter 14: External Diffusion Effects on Heteregeneous Reactions
Additional Homework Problems
CDP14-JB
A plant is removing a trace of Cl2 from a waste gas stream by passing it over a solid granular absorbant in a tubular packed bed (Figure CDP11-J). At present, 63.2% removal is being accomplished, but it is believed that greater removal could be achieved if the flow rate were increases by a factor of 3, and the packed bed tube length increased 50%. What percentage of chlorine would be removed under the scheme proposed? (The chlorine transferring to the absorbant is removed completely by virtually instantaneous chemical reaction.) (Ans: 98%)
What guidelines (T, v, CA) would you propose for efficient or optimum operation of this bed?
Figure CDP11-J
[3rd Ed. P11-5]